Дорогие коллеги, помогите перевести фразу mach# из документа Control Valve Specification

Pressure Drop (bar)
21.950
Choke Drop (bar (a))
17.715
Noise [IEC] (dBA)
100
Valve Vel (mach#)

Спасибо.

 San-Sanych

link 28.07.2017 10:52 
число Маха

 Aiduza

link 28.07.2017 10:53 
Mach number.

 DpoH

link 28.07.2017 12:35 
Учите матчасть... учитесь пользоваться гуглем
It has been the practice in the valve industry to use the Mach
number at the valve outlet to determine the velocity limitation in
a compressible flow application. The fluid Mach number is
defined as the ratio of fluid velocity over the velocity of sound in
a given fluid.A high outlet Mach number in control valves is an indication of high stream power and results in high noise level, induced vibration and erosion. The valve outlet Mach number should be limited
to avoid these problems.